Inspection History: PLUMBING - FINAL

Permit Number - T11PL01160

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
07/21/2011 PLUMBING - FINAL Approved IVRS - Inspection :*
07/19/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) VENT CONNECTOR TO BE ATTACHED TO DRAFT HOOD CORRECTLY AND ALL VENT CONNECTOR JOINTS TO HAVE FASTENERS (NO TAPE)
2) SECURE THE COPPER STUB OUTS AT THE WATER HEATER
3) STEEL STRAPPING AND BANG PLATE SHARP EDGES AT KITCHEN SINK AREA TO BE REMOVED FROM CONTACT WITH PEX TUBING
4) BREAK OFF VACUUM BREAKER TAMPER SCVREWS
5) PROVIDE BACKING TO SECURE MASTER BATH SHOWER/TUB VALVE AND SECURE VALVE
6) RAISE THE FRONT LANDSCAPING VACUUM BREAKER TO 12" ABOVE ALL DOWNSTREAM PIPING AND FINISH GRADE AND/OR PROVDIE APPROVED BACKFLOW PROTECTION FOR BOTH FRONT AND BACK LANDSCAPING WATER SUPPLIES
NOTE: BACK SYSTEM REQUIRES RPB OR PRESSSURE VACUUM BREAKER