Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T11PL01160
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/21/2011 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
07/19/2011 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) VENT CONNECTOR TO BE ATTACHED TO DRAFT HOOD CORRECTLY AND ALL VENT CONNECTOR JOINTS TO HAVE FASTENERS (NO TAPE) 2) SECURE THE COPPER STUB OUTS AT THE WATER HEATER 3) STEEL STRAPPING AND BANG PLATE SHARP EDGES AT KITCHEN SINK AREA TO BE REMOVED FROM CONTACT WITH PEX TUBING 4) BREAK OFF VACUUM BREAKER TAMPER SCVREWS 5) PROVIDE BACKING TO SECURE MASTER BATH SHOWER/TUB VALVE AND SECURE VALVE 6) RAISE THE FRONT LANDSCAPING VACUUM BREAKER TO 12" ABOVE ALL DOWNSTREAM PIPING AND FINISH GRADE AND/OR PROVDIE APPROVED BACKFLOW PROTECTION FOR BOTH FRONT AND BACK LANDSCAPING WATER SUPPLIES NOTE: BACK SYSTEM REQUIRES RPB OR PRESSSURE VACUUM BREAKER |