Inspection History Details
Inspection Status: Approved
Inspection History: SITE - SEWER
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/14/2012 | SITE - SEWER | Approved | ||
| 12/07/2011 | SITE - SEWER | Not ready for Inspection | IVRS - Inspection :* | |
| 09/19/2011 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) VACUUM TESTING MANHOLES, INSPECTING MANHOLE #2 AND MANHOLE #4 LOW PRESSURE TESTING TODAY |
|
| 09/13/2011 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) NEED TO FINISH LOW PRESSURE TESTING 2) NEED TO FINISH VACUUM TESTING |
|
| 09/12/2011 | SITE - SEWER | Not ready for Inspection | IVRS - Inspection :* 1) NOBODY ON SITE TO ASSIST INSPECTOR |
|
| 09/09/2011 | SITE - SEWER | Partial Approval | 1) STACK MANHOLES #2 & 3 2) BEGIN LOW PRESSURE AIR TEST |
|
| 09/08/2011 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) STACKED MANHOLE #11,8 & 1 2) POURED MANHOLE #2 & 3 |
|
| 09/07/2011 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) 6" SDR 35 TO CLEANOUT #4 FROM MANHOLE #2 2) POURED BASES FOR #8,11 AND 1 3) SDR FROM #9 TO #3 MANHOLE AND FROM #3 TO CLEANOUT #5 |
|
| 09/06/2011 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) JENSEN STACKING FIVE MANHOLES TODAY #9,10,6,7 & 4 2) FROM MANHOLE #7 TO MH #8 8" SDR 35 OK 3) FROM MH #8 TO MH #11 OK 4) FROM MH #8 TO CLEANOUT #10 OK 5) FROM MH #11 TO MH #1 OK TO COVER SUBJECT TO VERIFICATION OF GRADE AND TEST |
|
| 09/01/2011 | SITE - SEWER | Partial Approval | IVRS - Inspection :* ON 08/31/11 BASES POURED #9, #10 POURING #4, #6, #7 GA2 TODAY SDR35 FROM MH#6 TO MH #4 OK TO COVER DSR35 FROM MH#6 TO MH #7 OK TO COVER CLEANOUTS #8 #9 INSTALLED CLEANOUT #6, #7 INSTALLED |
|
| 08/31/2011 | SITE - SEWER | Not ready for Inspection | IVRS - Inspection :* 1) UNABLE TO LOCATE SUPER/CONTRACTOR IN JOB TRAILER AT 2 PM |
|
| 08/30/2011 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) 8" DIP EXTENDED FROM PUBLIC MANHOLE TO MANHOLE #10 2) 8" SDR 35 FROM MH #10 TO MH #9 3) 6" SDR 35 STUBBED UP FOR CLEANOUT #11 4) 8" SDR 35 STUBBED 20' TOWARDS MH #3 FROM MH #9 8" SDR 35 EXTEND TO MH #6 5) CALL IN INSPECTIONS FOR GASES 6) ALL PIPING SUBJECT TO VERIFICATION OF GRADE AND TEST AT A LATER DATE |
|
| 08/29/2011 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) 8" DIP EXTENDED 42' OUT OF PUBLIC MANHOLE-OK TO COVER, SUBJECT TO TEST AND VERIFICATION OF GRADE AT A LATER DATE |
|
| 08/26/2011 | SITE - SEWER | Partial Approval | 1) JENSEN WORKING ON PUBLIC MANHOLE | |
| 08/25/2011 | SITE - SEWER | Partial Approval | IVRS - Inspection :* WORK ON PUBLIC MANHOLE TODAY |