Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T11PL01039

Parcel: 137100300


Addresses:

776 W DAKOTA DR

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
06/23/2011 PLUMBING - FINAL Approved IVRS - Inspection :*
06/21/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) REPAIR OR REPLACE WATER HEATER/FURNACE VENT CAP AND PROVIDE AN APPROVED GAS SHUT OFF VALVE AT WATER HEATER PRIOR TO TURN ON
2) PROVIDE RIDGID NIPPLE THRU FURNACE APPLIANCE SIDE WALL
3) PROVIDE BONDING OF BLDG GAS SYSTEM