Permit: T11PL01023

Parcel: 127031100


Addresses:

5731 E 2ND ST

Inspection Status: Not ready for Inspection

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
07/01/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) OK TO BACKFILL
2) MAKE CORRECT T & P DRAIN TO APPROVED LOCATION WITH APPROVED MATERIALS
06/29/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) ALL FITTINGS AND PIPE MARRED BY WRENCHES TO BE PRIMED, THEN HALF OVER LAPPED DBL WRAPPED WITH 10 MIL PVC TAPE
2) PVC NOT APPROVED FOR T & P RELIEF DRAIN, MAY NOT DIRECTLY CONNECT T & P RELIEF DRAIN TO SANITARY SEWER
3) USE 3 SCREWS ON EACH END OF VENT CONNECTION