Permit: T11PL00989

Parcel: 111063420

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
06/21/2011 PLUMBING - FINAL Approved IVRS - Inspection :*
06/15/2011 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ABS REQUIRES A MINIMUM OF 12" OF COVER. LESS THAN 12" OF COVER USE CAST IRON
2) TRACER WIRE COLOR FOR SEWER IS GREEN, NOT BLUE
3) REQUIRE A MINIMUM OF 1 PERCENT SLOPE
4) CONTRACTOR TO PAY REINSPECTION FEE
5) PROVIDE EVIDENCE THAT SEPTIC TANK HAS BEEN PUMPED AND BROKEN
06/14/2011 PLUMBING - FINAL Denied 1) FAILURE TO COMPLY WITH PREVIOUSLY NOTED ITEMS WILL RESULT IN A REINSPECTION FEES. INSPECTION HISTORY SHALL BE ON SITE AT AL TIMES
06/13/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) UNIT NO MUMBERED CORRECTLY
2) UNABLE TO LOCATE PLAN OR PERMIT
3) COULDN'T FIND SEPTIC TANK
4) TANK TO BE PUMPED, BROKEN, INSPECTED AND REFILLED
5) ABS REQUIRES A MINIMUM OF 12" OF COVER
6) PIPING LESS THAN 12" DEEP TO BE APPROVED MATERIAL