Permit: T11PL00988

Parcel: 111063420

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
06/21/2011 PLUMBING - FINAL Approved IVRS - Inspection :*
06/15/2011 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ABS REQUIRES MINIMUM 12" OF COVER
2) TRACER TO BE GREEN, NOT BLUE
3) REQUIRE AT LEAST 1 PERCENT SLOPE
4) CONRACTOR TO PAY REINSPECTION FEE
5) PROVIDE EVEIDENCE THAT SEPTIC HAS BEEN PUMPED AND BROKEN
06/13/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) UNIT NOT NUMBERED CORRECTLY
2) UNABLE TO LOCATE PLAN OR PERMIT
3) COULDN'T FIND SEPTIC TANK
4) TANK TO BE PUMPED, BROKEN, INSPECTED AND FILLED
5) MISSION BANDS ON NEW ABS INDICATE A REPAIR
6) NEW CONSTRUCTION REQUIRES YOU TO USE APPROVED MATERIAL, IE.....SOLVENT WELD COUPLINGS