Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/22/2011 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 06/13/2011 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) PROVIDE PROPER SUPPORT ON CSST 2) SUPPORT ALL TEES AT THE IRON PIPE FITTINGS AND AT STOVE S.O.V. AND INSTALL SOV OUTSIDE OF WALL 3) CORRECT FURNACE DUCTS AND VENTS 4) PROVIDE SUPPORT AND MINIMUM CLEARANCES 5) A PERMIT IS REQUIRED FOR MECHANICAL UNIT 6) RELOCATED WATER HEATER IS MISSING A SHUT OFF VALVE AND PIPE CLAMPS ON THE WATER SUPPLY, ALSO APPROVED RELIEF DRAIN PIPING WITH NO RESTRICTIONS 7) NO TAPE AT B VENT CONNECTION, SECURE WITH SCREWS 8) PROVIDE PROTECTION PLATES FOR CSST PASSING THRU TOP PLATE-SEE INSTALLATION REQUIREMENTS |