Permit: T11PL00960

Parcel: 107030960


Addresses:

2526 N JONATHAN AV

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
07/18/2011 PLUMBING - FINAL Approved IVRS - Inspection :*
06/15/2011 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
1) RELIEF VALVE MAY NOT BE TRAPPED
2) HARD PIPE WITH APPROVED MATERIALS
3) REMOVE TAPE FROM FLARED JOINTS
06/10/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) PROVIDE A MINIMUM OF 12" OF COVER
2) PRIME AND WRAP ALL JOINTS BELOW GRADE
3) TEST ENTIRE SYSTEM
4) LOWER RELIEF DRAIN IN WALL AND CONNECT TO VALVE AT NEW HEATER, CHECK FOR PROPER OPERATION
5) SUPPORT GAS PIPING AT FURNACE: INSTALL SEDIMENT TRAPS, SECURE VENTS WITH SCREWS AND ELECTRICAL BONDING
06/07/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) NO ONE HOME
2) ACCESS REQUIRED FOR INSPECTION
3) HAND OUT PROVIDED