Permit: T11PL00868

Parcel: 106062450


Addresses:

1055 W SIMMONS ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
06/24/2011 PLUMBING - FINAL Approved IVRS - Inspection :*
06/15/2011 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
1) SECURE TRACER WIRE TO RISERS ABOVE GRADE
2) OK FOR GAS
3) CORRECT FURNACE VENT CONNECTION AT COMMON TEE
06/10/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) SECURE PIPING BEHIND STOVE
2) CORRECT DIRECTION OF FLOW ON FURNACE VENT CONNECTORS
3) EXTEND VENT TERMINATION AS REQUIRED ABOVE COOLER
4) SECURE RED WOOD BLOCKS TO ROOF WITH TAR
5) SECURE FLASHINGS WITH ROOFING SCREWS
6) PROVIDE PETITION OF APPEAL FORM WITH SIGNATURE FOR ALTERNATE RELIEF DRAIN TERMINATION
7) PLUG PAN AND PROVIDE 1" AIR GAP ABOVE PAN
06/08/2011 PLUMBING - FINAL Cancelled CANCELLED PER LUKE OF COMMUNITY HOME REPAIR #745-2055
06/07/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*