Permit: T11PL00861

Parcel: 10711072B


Addresses:

243 E DELANO ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
05/20/2011 PLUMBING - FINAL Approved IVRS - Inspection :*
05/18/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
NOTE: ONE PERMIT FOR 2 SEPERATE BLDG USED FOR INCOME
1) WATER REQUIRES; CORRECTLY INSTALLED VENT CONNECTORS SECURED WITH GALV. SCREWS
2) 3/4 GALV WATER SUPPLY WITH FULL SIZED AND FULL PORTED VALVE
3) REMOVE FLEX AND BLK COUPLING ON RELIEF DRAIN
4) PETITION OF APPEAL REQUIRED OK
5) PLUG PAN
6) INSTALL SEDIMENT TRAP AT WATER HEATER AND FURNACE GAS SUPPLY
7) EXTEND B VENT TERMINATION AS REQUIRED ABOVE FORCED AIR INTLET
UNIT 243:
1) COMPLETE GAS TO FURNACE
2) WATER HEATER B VENT