Permit: T11PL00842

Parcel: 121061340

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
05/12/2011 PLUMBING - FINAL Approved IVRS - Inspection :* TYPE B VENT REQURIES MIN 1" CLEARANCE (ATTIC)
CORRECT FURNANCE VENT, IT HAS COME APART. ALSO SEACURE WH VENT W/GALV SCREWS.
FLEX NOT APPROVED ON RELIEF DRAIN.
REPLACE SEIZED UP RELIEF VALVE
SUDIMENT TRAPS REQUIRED
SLECTRUST BONDING REQ
A PERMIT OR VACUUM BREAKER IS REQUIRED
GR VALVE REPLACEMENT (HOSE BIB)
05/09/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) ARE BOTH UNITS SUPPLIED WITH ONE METER ?
2) DID YOU REPLACE THE PIPING AS DESCRIBED ? IF SO A PLAN IS REQUIRED
3) PROVIDE ACCESS TO ALL GAS APPLIANCES ON THIS SYSTEM
4) TEST WITH A 15 PSI GAUGE
5) NEW HOSE BIB REQUIRES A VACUUM BREAKER