Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - YARD WTR LINE/TEST
Permit Number - T11PL00829
Inspection Description - PLUMBING - YARD WTR LINE/TEST
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/06/2011 | PLUMBING - YARD WTR LINE/TEST | Approved | IVRS - Inspection :* | |
05/05/2011 | PLUMBING - YARD WTR LINE/TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) EXPOSE PIPING FOR INSPECTION 2) PROVIDE VACUUM BREAKER ON HOSE BIB 3) PROVIDE CORRECT BACKFLOW PROTECTION DEVICE FOR LANDSCAPING SYSTEM WITH VALVE DOWN STREAM OF ATMOSPHERIC VACUUM BREAKER 4) PVC SCHEDULE 40 REQURIES FITTINGS AT CHANGE OF DIRECTION |