Permit: T11PL00793

Parcel: 120022080


Addresses:

4315 S 16TH AV

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
05/16/2011 PLUMBING - FINAL Approved IVRS - Inspection :*
05/10/2011 PLUMBING - FINAL Cancelled CANCELED PER CONTRACTOR DAN OF COMMUNITY HOME PROJECT #745-2055
05/10/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) CANCELED
05/05/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) SUPPORT AND SECURE GAS PIPING TO WATER HEATER
2) VENT FROM WATER HEATER TO BE MADE UP CORRECTLY. REMOVE ALL TAPE AND PROVIDE FASTENERS AT ALL CVENT CONNECTOR JOINTS. PROVIDE 1" MINIMUM CLRNACE FOR DBL WALL VENT AND COMBUSTIBLE ROOF SHEATHING AT ROOF
3) SUPPORT AND SECURE GAS PIPING TO STOVE
4) MAKE UP FURNACE VENT CORRECTLY, REMOVE ALL TAPE AND PROVIDE FASTENERS AT VENT CONNECTOR JOINTS