Permit: T11PL00773

Parcel: 131031030


Addresses:

5118 E ANDREW ST

Inspection Status: Partial Approval

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
05/02/2011 PLUMBING - FINAL Partial Approval IVRS - Inspection :* THE COMBUSTION AIR VENT MUST BE WITHIN 12" OF THE CEILING. PROVIDE SCREENS IN COMBUSTION AIR OPENINGS. OK TO BACKFILL TRENCH. 15 PSI TEST IS OK. LEFT GAS CARD
04/29/2011 PLUMBING - FINAL Denied IVRS - Inspection :
There is no access to the site.| 920*
04/27/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :* INSTALL FULL SIZED PIPING TO HOUSE CONNECTION AND 3/4 TO FURNACE
TEST ALL PIPING
PROVIDE COMBUSTION AIR FROM THE EXTERIOR TO WH CLOSET IN BEDROOM
PROVIDE AN OPERATIOIN RELIEF VALVE
PRIME & WRAP ALL TOOL MARKS BELOW GRADE
PROVIDE A 10 PSI TEST W/ A 15 PSI BACK