Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T11PL00732
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/19/2011 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* 1) ABS DWV, PEX OK-OK TO COVER |
|
05/17/2011 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) WASHER TRAP TO HIGH |
|
05/13/2011 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) MINIMUM SIZE WASTE FOR WASHER TO BE 2" WASHER REQUIRES A VENT 2) SANTEE ON IT'S BACK IS NOT A DRAINAGE FITTING. USE A COMBO. HOW ARE SINKS TO BE VENTED ? 3) HORIZONTAL X HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP 4) WATER TEST REQUIRED 5) SEWER OK TO COVER |