Permit: T11PL00533

Parcel: 129063980


Addresses:

2201 E 21ST ST


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T11PL00533

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
03/23/2011 PLUMBING - FINAL Approved IVRS - Inspection :*
03/22/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) OFF SET PIPING DOWN AT METER LOCATION IN ORDER TO PROVIDE THE MINIMUM 12" OF COVER REQUIRED
2) PROVIDE 10' OF COPPER BELOW GRADE TO SUPPORT THE ELECTRICAL BOND
3) COMPLETE THE VACUUM BREAKER INSTALLATION
4) IS A BACK FLOW PREVENTION ASSEMBLY REQUIRED ?