Permit: T11PL00483

Parcel: 136086190


Addresses:

1620 S BARBADOS PL

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
03/29/2011 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
03/15/2011 PLUMBING - GAS PRESSURE TEST Denied 1. TEST PIPING SYSTEM IN ITS ENTIRETY. 2. PROVIDE PROOF P.E. PIPING DOES NOT GO UNDER BUILDING FOUNDATION. 3. VENT FROM WATER HEATER TO BE PROPERLY ATTACHED TO DRAFT HOOD AND VENT TO HAVE FASTENERS AT ALL JOINTS. 4. PROVIDE ONE INCH CLEARANCE FROM WOOD AT ROOF AND DOUBLE WALL VENT PIPING AT WATER HEATER. 5. PROVIDE 90 DEGREE DOWN TERMINATION ON T AND P DRAIN PIPE FOR WATER HEATER. 6. PROVIDE A GAS ISOMETRIC OF THIS SYSTEM. PROVIDE LADDER FOR ROOF TOP ACCESS TO APPLIANCES. VERIFY BONDING OF GAS SYSTEM. PROVIDE COMBUSTION AIR TO WATER HEATER. LIST MAY NOT BE COMPLETE.