Permit: T11PL00475

Parcel: 11462011C

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
05/12/2011 PLUMBING - FINAL Approved IVRS - Inspection :*
1) REMOVE ROCKS AND DEBRIS FROM DITCH AND BACKFILL WITH 1/2" MINUS MATERIAL
05/10/2011 PLUMBING - FINAL Cancelled CANCELED PER ALICIA OF TRIUMPH AIR #408-7444
05/10/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) CANCELED
03/25/2011 PLUMBING - FINAL Denied RESEAL ALL PIPE PENETRATIONS THRU ROOF. ALL UNDERGROUND TOOL MARKS AND FITTINGS TO BE COVERED WITH PIPE TAPE PRIMER, THEN WRAPPED WITH PIPE TAPE TO ACHIEVE A 40 MIL THICKNESS OF PIPE WRAP. CONTRACTOR TO PAY REINSPECTION FEE PRIOR TO FINAL INSPECTION UNDERGROUND PIPING TO STAY UNCOVERED UNTIL FINAL APPROVAL
03/22/2011 PLUMBING - FINAL Cancelled IVRS - RI canceled
03/17/2011 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PIPE TEST TO BE IN PLACE WITH 10 PSI TEST HOLDING FOR 15 MINUTES TO ALL APPLIANCES AND INTO HEARTH OF FIRE PLACE
2) PIPING TO BE PROPERLY BEDDED AND HAVE SEPERATION. PIPE CANNOT BE STACKED ON TOP OF EACH OTHER UNDERGROUND
3) ALL UNDERGROUND TOOL MARKS AND FITTINGS TO BE PRIMED THEN WRAPPED TO ACHEIVE 40 MIL THICKNESS
4) ROOF TOP PIPING TO BE PROPERLY SECURED AND SUPPORTED WITH WEATHER RESISTANT METHODS