Permit: T11PL00382

Parcel: 113072280


Addresses:

2919 N CHERRY AV

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
04/01/2011 PLUMBING - FINAL Approved IVRS - Inspection :*
03/21/2011 PLUMBING - FINAL Not ready for Inspection 1. USE WATER PROOF WIRE NUTS. 2. PEX IS NOT LISTED TO BE INSTALLED EXPOSED ON A WALL.
03/15/2011 PLUMBING - FINAL Not ready for Inspection 1. REQUIRE TWELVE INCHES OF TRACER TO BE VISIBLE AT THE METER VALVE. 2. REQUIRE WATER PROOF WIRE NUTS FOR CONNECTED TRACER WIRES. 3. SEAL EXTERIOR WALL PENETRATIONS. 4, BREAK OFF RETAINING SCREW ON AVB.
03/07/2011 PLUMBING - FINAL Not ready for Inspection 1. YARDWATER PIPING COVERED WITHOUT INSPECTION. 2. NOBODY HOME.
03/04/2011 PLUMBING - FINAL Partial Approval 1. WASHER BOX REQUIRES HAMMER ARRESTORS. 2. OK TO COVER WALLS.