Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 03/04/2011 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection :* |
| 03/01/2011 |
PLUMBING - FINAL |
|
Not ready for Inspection |
1.PROVIDE CORRECT FULL SIZE VENT WYE FITTING FOR WATER HEATER/FURNESS. NOTE: APPLE PLUMBING AND COOLING APPEARS TO HAVE INSTALLED WATER HEATER, A/C FURNESS, WITHOUT PERMITS. PROVIDE PERMITS OR PROOF OF INSPECTION. CORRECTIONS INCLUDE: A. CORRECT DISCHARGE TERMINATION FOR CONDENSATE PUMP PIPING, PROPERLY SUPPORTED, INSULATION FOR LINE SET, PROPERLY SUPPORTED AND PROTECTED FROM UV SUN EXPOSURE. VENT TEMINATION TO EXTEND A MIMIMUM OF THREE FEET ABOVE INTAKE WITH DOUBLE WALL VENT PIPING WITHIN TEN FEET OF INTAKE, PROVIDE OVERFLOW SENSOR, CAP OCD CONDENSATE DRAIN PIPING IN A/C FURNESS CLOSET. |