Permit: T11PL00376

Parcel: 134081980


Addresses:

8526 E 20TH ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
03/04/2011 PLUMBING - FINAL Approved IVRS - Inspection :*
03/01/2011 PLUMBING - FINAL Not ready for Inspection 1.PROVIDE CORRECT FULL SIZE VENT WYE FITTING FOR WATER HEATER/FURNESS. NOTE: APPLE PLUMBING AND COOLING APPEARS TO HAVE INSTALLED WATER HEATER, A/C FURNESS, WITHOUT PERMITS. PROVIDE PERMITS OR PROOF OF INSPECTION. CORRECTIONS INCLUDE: A. CORRECT DISCHARGE TERMINATION FOR CONDENSATE PUMP PIPING, PROPERLY SUPPORTED, INSULATION FOR LINE SET, PROPERLY SUPPORTED AND PROTECTED FROM UV SUN EXPOSURE. VENT TEMINATION TO EXTEND A MIMIMUM OF THREE FEET ABOVE INTAKE WITH DOUBLE WALL VENT PIPING WITHIN TEN FEET OF INTAKE, PROVIDE OVERFLOW SENSOR, CAP OCD CONDENSATE DRAIN PIPING IN A/C FURNESS CLOSET.