Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T11PL00367

Parcel: 134101190


Addresses:

8061 E HAYNE ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
04/13/2011 PLUMBING - FINAL Approved IVRS - Inspection :*
03/25/2011 PLUMBING - FINAL Denied TEST TO HOLD FOR 15 MINUTES WITH NO LOSS OF PRESSURE
03/09/2011 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SYSTEM NOT HOLDING PRESSURE
2) EVERYTHING ELSE OK
02/28/2011 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE APPROVED GAS SHUT OFF VALVE AT STOVE
2) CLAMP GAS LINE TO BLOCK ON ROOF
3) PROVIDE TAPE PRIMER AND 40 MILS OF TAPE ON ALL BURIED JOINTS AND TOOL MARKS
4) PROVIDE A TEST ON ALL GAS PIPING WITH A 15 POUND GAUGE