Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/14/2011 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* | |
| 04/12/2011 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* | |
| 04/05/2011 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* YOU SEEM TO HAVE AN ADDRESSING PROBLEM. THERE IS NO ADDRESS POSTED 1812 W MERLIN RD | |
| 02/25/2011 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* 1) POST CORRECT ADDRESS 2) TEST SYSTEM WITH A 15 PSI GAUGE 3) CORRECT RELIEF DRAIN LINE 4) INSTALL AN OPERABLE T & P SAFETY VALVE 5) SUPPORT GAS PIPE AT SOV 6) SEDIMENT TRAPS GO AFGER THE SOV 7) AT FURNACE EXTEND HARD PIPE THRU FIRE BOX 8) CORRECT VENT CONNECTION 9) PROVIDE ELECTRICAL BONDING |