Inspection History Details
Inspection Status: Approved
Inspection History: SITE - SEWER
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/21/2011 | SITE - SEWER | Approved | IVRS - Inspection :* | |
| 03/30/2011 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) DISCUSSED SEWER CONNECTIONS FOR MODULARS WITH ? |
|
| 03/11/2011 | SITE - SEWER | Not ready for Inspection | IVRS - Inspection :* | |
| 03/10/2011 | SITE - SEWER | Partial Approval | VAC. TESTING MANHOLE#2, 3, 4 OK. AIR TESTING 6", 8" MIRROR AND MANDREL 8". | |
| 03/09/2011 | SITE - SEWER | Not ready for Inspection | IVRS - Inspection :* | |
| 03/08/2011 | SITE - SEWER | Not ready for Inspection | IVRS - Inspection :* | |
| 03/07/2011 | SITE - SEWER | Partial Approval | 1. STACK MANHOLES #2, #3, AND NUMBER 4. | |
| 03/04/2011 | SITE - SEWER | Partial Approval | 1. 6' SDR 35 BRANCH FROM MANHOLE #4 WITH DIP. | |
| 03/03/2011 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) MAN HOLE #2,3 AND 4 BASES POURED |
|
| 03/02/2011 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) 8" SDR 35 BETWEEN UNIT #3 AND 4 OK 2) SUBJECT TO TEST AND V.O.G. 3) 6" SDR 35 EXTENDED TO NEXT UPSTREAM CLEANOUT 4) OK TO COVER |
|
| 03/01/2011 | SITE - SEWER | Partial Approval | 1. MANHOLE #2 TO MANHOLE #3 . 8' SDR 35 OK TO COVER SUBJECT TO VERIFICATION OF GRADE AND TEST AT A LATER DATE. | |
| 02/28/2011 | SITE - SEWER | Partial Approval | 1. 8' SDR 35 BETWEEN MANHOLES NUMBER ONE AND MANHOLE NUMBER TWO. | |
| 02/25/2011 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1) 8" SDR35 FROM MH #1 TO MH #2 OK TO COVER SUBJECT TO VERIFICATION OF GRADE AND TEST AT A LATER DATE |