Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
02/24/2011 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
02/14/2011 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 1/2" IS UNDERSIZED AT WH/FURNACE
2) SEDIMENT TRAPS REQUIRED AFTER APPLIANCE SOV
3) SEAL ABANDON PIPING IN HOME
4) NEW WATER HEATER AND FURNACE REQUIRE APPROVED TYPE B VENTING THRU ROOF
5) APPROVED FLASHING REQUIRED AT ROOF PENETRATIONS
6) INSTALL FLASHINGS AS REQUIRED (SCREWS ON ALL SIDES) BY INSTALLATION INSTRUCTIONS
7) PROVIDE ELECTRICAL BONDING
8) PIPE T & P TO APPROVED WASHER BOX OR PROVIDE A SINGED PETITION OF APPEAL FORM