Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/19/2011 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* | |
| 04/18/2011 | PLUMBING - GAS PRESSURE TEST | Partial Approval | IVRS - Inspection :* | |
| 04/12/2011 | PLUMBING - GAS PRESSURE TEST | Cancelled | CANCELLED PER WARREN #631-6431 | |
| 04/06/2011 | PLUMBING - GAS PRESSURE TEST | Partial Approval | IVRS - Inspection :* 1) 60 PSI TEST FROM METER TO VALVES NEAR APPPLIANCES 2) 2 APPLIANCES REQUIRE 7" TO 9" WC INLET PRESSURE 3) 1 APPLIANCE REQUIRES 7" INLET PRESSURE 4) THIS REQUIRES A MEDIUM PRESSSURE METER SET WITH CITY APPROVED REVISED PLAN FOR REGULATION OF PRESSSURE AT APPLIANCES, CORRECT VENTING OF APPLIANCES AND TERMINATION OF PRESSURE RELIEF DEVICES 5) CONTACT STATE BOILER INSPECTOR FOR INSEPCTION OF BOILER 6) TERMINATE REGULATOR VENTS AS REQUIRED WITH RETEST AT LINE PRESSURE FROM METER |
|
| 04/05/2011 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* |