Inspection History Details
Inspection Status: Approved
Inspection History: FIRE - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/21/2011 | FIRE - FINAL | Approved | ||
| 01/27/2011 | FIRE - FINAL | Denied | Not approved 1/26/11 1.) Will require separate permit for Ice Cream Parlor. 2.) Address numbers must be at least 12 inches tall and color must contrast with background. 3.) The security screen door and thumb-turn lock, main exit, must be readily openable at all times. (Door sticks at bottom, thumb lock hard to turn open) 4.) Exit sign over front door is burnt out. 5.) Emergency back-up lighting for front exit is burnt out. 6.) Extension cords are for temporary use only and not a substitute for permanent wiring. 7.) Portable fire extinguishers must be labled. 8.) Remove portable space heater away from combustibles. 9.) Extension cords must be protected from pedestrian traffic at all times. 10.) The storage of merchandise must be orderly . 11.) The accumulation and storage of merchandise must not reach the point of creating exessive fire hazard and or creating an obstruction on exiting. (access, exit or discharge) 12.) Must remove the curtain that is obstructing the view of the secondary exit. 13.) Must have a clear and unobstruted pathway to the exit at all times (pathway to rear exit) 14.) Need an emergency back-up light for the rear exit. 15.) Area around an emergency back-up light must be clear from objects that will obstruct the lighting of the exit pathway. 16.) Cover opening in the ceiling located in the womens bathroom. 17.) Secure all compressed gas cylinders. 18.) Remove slide-bolt locks from rear exit door and replace with thum-turn lock. 19.) Only one lock per door is permitted. 20.) Area around hot water heater must be clean and clear of combustibles at all times. 21.) Cover opening in ceiling located in the storage located just behind the ice cream parllor. 22.) Repair lose door hinge on door leading into parllor. 23.) Need illuminated exit sign for the exit door located on the south wall. 24.) Need a thumb-turn lock for same door. 25.) Need a clear working area around any electrical panel. 26.) Appliance cord for the ballast light over the work bench located in the work area is spliced (splicing is prohibited) 27.) Any wiring that is not in service must be secured or removed. 28.) Need a directional exit sign for rooms leading out to the south wall exit. 29.) Need a,"NOT AN EXIT" sign for the door located on the north wall that leads out to an enclosed area. 30.) Remove the keyed lock from sam door and replace with a thumb-turn lock. 31.) Remove keyed lock from the security screen door form the same north wall door and replace with a thumb-turn lock. 32.) Provide and maintain an exit path under the awning. PARLLOR 33.) Extension cords are for temporay use ony. 34.) Cover the opening in the wall located behind the soda cooler. 35.) Door on rear wall next to video game must be labled, "NOT AN EXIT" 36.) Replace broken cover plate located next to video game. 37.) The security door for the front exit must be locked in the open postion at all times when the building is occupied. |