Permit: T11OT00086

Parcel: 13110034A


Addresses:

5590 E 22ND ST

Inspection Status: Approved

Inspection History: SIGN ELECTRIC

Date Description Inspector Results Comments
02/02/2011 SIGN ELECTRIC Approved IVRS - Inspection :*
02/01/2011 SIGN ELECTRIC Denied IVRS - Inspection :
See detailed listing on site.| 999*
DENIED- NO MSG
RECALL INSP, LEAVE MSG WITH CONTACT PH# OR MEET INSPECTOR ON SITE