Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/16/2011 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* | |
| 11/15/2011 | MECHANICAL - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 11/14/2011 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE GAS PRESSURE TEST ON NEW PIPING TO FURNACE 2) PROVIDE MINIMUM R-8 FLEX DUCT IN VENTED ATTIC 3) ALL CANS IN ATTIC ARE TO BE INSULATED R-8 4) PROVIDE MINIMUM 1" CLEARANCE TO COMBUSTIBLE MATERIALS FROM B-VENT 5) CEILING BOOTS NOT PROPERLY INSTALLED 6) THIS IS A NEW INSTALLATION REVISE PERMIT TO REFLECT AS SUCH, INCLUDE GAS PIPING, ELECTRIC AND ALSO PROVIDE ISOMETRIC PIPING DIAGRAM AND LOAD CALC FOR UNIT WEIGHT NOTE: THIS PERMIT WAS INTENDED TO INCLUDE GAS PRESSURE TEST FOR RECONNECT, PLEASE ADD TO PERMIT |