Inspection History Details
Inspection Status: Denied
Inspection History: MECHANICAL - FINAL
Permit Number - T11ME00211
Inspection Description - MECHANICAL - FINAL
Inspection Status - Denied
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/17/2011 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) DISCONNECT NOT PROPERLY MOUNTED 2) DO NOT LAND 2 WIRES ON A SINGLE LUG (SURGE PROTECTOR) 3) ALL ELECTRIC WIRING PENETRATING CABINET MUST HAVE AN APPROVED TIGHTLY FASTENED CLAMP 4) PROVIDE MINIMUM 6" CLEARANCE TO COMBUSTIBLES AT FLUE PIPE 5) PROVID GASKET AT RETURN AIR OPENING 6) CONDENSATE CANNOT TERMINATE AT A WASTE VENT |