Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - INTERMEDIATE
Permit Number - T11ME00123
Inspection Description - MECHANICAL - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/23/2011 | MECHANICAL - INTERMEDIATE | Approved | ||
05/02/2011 | MECHANICAL - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* CONDENSATE CONNOT TERMINATE INTO A LOWER VENT. PROVIDE THE REQUIRED STRUCTURED DRAWING FOR NEW A/C ON ROOF PROVIDE THE REQUIRED GFI SERVICE RECEPTACLE ON ROOF. REPAIR BROKEN CONNECTION TO RECEPTACLE MARK UNIT DATA PLATES W/ PROPER HEAT STRIPES & FUSE ACCORDINGLY. PAINT EXPOSED PVC W/LATEX PAINT & SUPPORT 4' INSULATE METAL PLENUMS IN ATTIC WITH MIN R8 INSULATION & PROVIDE R8 FLEX DUCTS |