Permit: T11ME00049

Parcel: 137040450


Addresses:

5315 S CHAMPION SV

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
03/02/2011 MECHANICAL - FINAL Approved
02/25/2011 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
02/23/2011 MECHANICAL - FINAL Not ready for Inspection IVRS - Inspection :*
02/17/2011 MECHANICAL - FINAL Not ready for Inspection IVRS - Inspection :*
1) REFRIDGERATION PIPING NOT INSULATED
2) ALL PIPE PENETRATIONS TO HAVE ROOF JACKS
3) PROVIDE APPROVED SERVICE OUTLET
4) CONDENSATE CANNOT TERMINATE AT WASTE VENT
5) NEUTRAL WIRE NOT TO BE USED AS A HOT LEG
6) PROVIDE BLOCKING AT GAS PIPING ON ROOF
7) FLUE PIPING NOT PROPERLY INSTALLED
8) PROVIDE SECONDARY DRAIN AT INDOOR COIL
9) ALL PVC JOINTS TO HAVE PRIMER, PRIMER IS TO BE PURPLE IN COLOR
10) PROVIDE COMBUSTION AIR AT MECHANICAL CLOSET
11) PROVIDE BARRIER BETWEEN RETURN PLENIUM AND MECHANICAL CLOSET