Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/01/2011 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* | |
| 02/24/2011 | MECHANICAL - FINAL | Partial Approval | IVRS - Inspection :* 1) PROVIDE PROTECTIVE COATING ON ARMAFLEX AT CONDENSOR 2) DO NOT USE SINGLE WALL PIPE TO EXTEND DBL WALL 3) PROVIDE THE SAME MANUFACTURER DBL WALL PIPE AS THE EXISTING |
|
| 02/02/2011 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* DENIED- 1-PROVIDE A PERMIT FOR 2 NEW WATER HEATERS 2-PROVIDE 6" CLEARANCE FROM LINE SET INSULTION TOUCHING VENT CONNECTOR.TAPE IS FALLING OFF INSULATION. 3-PROVIDE PROTECTIVE COATING ON EXPOSED ARMAFLEX. 4-LOW VOLTAGE WRIE MUST BE PROTECTED FROM DAMAGE BY RODENTS. 5-EXTEND FURNACE/WATER HEATER VENT MIN 3" ABOVE COMBUSTION AIR INTAKE. 6-PROVIDE A GFI RECEPTACLE AT CONDENSOR. |