Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/17/2011 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* | |
| 02/03/2011 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* DENIED- PROVIDE MIN 6" CLEARANCE WHERE ARMAFLEX IS HEAR VENT CONNECTOR. CONNECT THE OVERFLOW SENSOR OR CONDENSATE PUMP. PROVIDE A RECPTACLE FOR PUMP AND FURNACE. SRU BOX NOT REQUIRED. CONDENSATE CANNOT TERMINATE INTO A SEWER VENT. PROVIDE A PROTECTIVE COATING ON EXPOSED ARMAFLEX. PROVIDE THE REQUIRED STRUCTURAL ROOF DRAWING FOR A/C UNIT ON ROOF. SECURE THE ELEC DISCONNECT BETTER. SECURE ANGLE IRON FRAME TO THE ROOF. PROVIDE THE REQUIRED GFI SERVICE RECEPTACLE AT THE CONDENSOR. USE ONLY DOUBLE WALL VENT PIPE TO EXTEND VENT ABOVE THE COOLER. NO SINGLE WALL ALLOWED. |