Case: T11FR00080

Parcel: 13414020E


Addresses:

1122 S PANTANO RD


Inspection Status: Approved

Inspection History: INSP - FULL

Case Number - T11FR00080

Inspection Description - INSP - FULL

Inspection Status - Approved

Date Description Inspector Results Comments
01/13/2011 INSP - FULL Approved
01/10/2011 INSP - FULL Correction Required 1. _____ 703.1 Maintenance. The required fire-resistance rating of fire-resistance-rated construction (including walls, fire stops, shaft enclosures, partitions and floors) shall be maintained. Such elements shall be properly repaired, restored or replaced when damaged, altered, breached or penetrated.
- REPLACE MISSING CEILING TILE IN THE REAR OFFICE

2. _____ 1008.1.8.4 Bolt locks. Manually operated flush bolts or surface bolts are not permitted.
- REAR EXIT

3. _____ 901.4 Installation. Fire protection systems shall be maintained in accordance with the original installation standards for that system. Systems shall be extended, altered, or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards.
-REPLACE MISSING FIRE EXTINGUISHER

4. _____ 407.4 Training. Persons responsible for the operation of areas in which hazardous materials are stored, dispensed, handled or used shall be familiar with the chemical nature of the materials and the appropriate mitigating actions necessary in the event of
a fire, leak or spill…
- Train employees on the location of the MSDS/ Hazardous Communication Program.

5. _____ 605.6 Unapproved conditions. Open junction boxes and open-wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes.
- REPLACE MISSING ELECTRICAL COVERPLATES IN DR. BIRD'S OFFICE & KITCHEN

6. _____ 1008.1.8.3 Locks and latches. Locks and latches shall be permitted to prevent operation of doors where any of the following exits:
" Places of detention or restraint.
" In buildings in occupancy Group A having an occupant load of 300 or less, Groups B, F, M and S, and in churches, the main exterior door or doors are permitted to be equipped with key-operated locking devices from the egress side provided:
2.1. The locking device is readily distinguishable as locked,
2.2. A readily visible durable sign is posted on the egress side on or adjacent to the door stating: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. The sign shall be in letters 1 inch (25mm)high on a contrasting background,
2.3. The use of the key-operated locking device is revokable by the fire code official for due cause.
- PROVIDE THE SIGN ON THE FRONT DOORS