Permit: T11EL03301

Parcel: 12218126A

Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
02/16/2012 ELECTRIC - RECONNECT Approved IVRS - Inspection :*
02/13/2012 ELECTRIC - RECONNECT Partial Approval IVRS - Inspection :*
1) GROUNDING ELECTRODE CONDUCTOR TO TERMINATE TO GROUNDED CONDUCTOR
2) USE APPROVED MOUNTING SCREWS-NOT DRYWALL SCREWS
3) IN GUTTER INSTALL GROUNDED BAR
4) FINISH SUB PANEL
5) FINISH GROUNDING ELECTRODE SYSTEM AND GAS BOND
6) OK INTERIOR
02/10/2012 ELECTRIC - RECONNECT Cancelled IVRS - RI canceled
02/09/2012 ELECTRIC - RECONNECT Cancelled IVRS - RI canceled
02/07/2012 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
01/30/2012 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
FRONT LIGHT:
1) EXPOSED CONDUCTORS MADE UP OUTSIDE LIGHT
2) STRAP CONDUIT BACKSIDE OF HOUSE
3) NON CODE COMPLIANT WIRING ON BACK OF UNITS
4) EXTERIOR DISCONNECT AND WIRE WAY IN DETERIORATED CONDITION
5) ENTIRE SERVICE IN DETERIORATED CONDITION
6) MISSING GROUNDING ELECTRODE SYSTEM
7) BROKEN RECEPTS
8) INTERIOR PANEL NOT CODE COMPLIANT AT TIME OF INSTALL
9) NUMEROUS VIOLATIONS
10) WATER HEATER NOT WIRED TO CODE
11) GFI'S NEEDED FOR REPLACED RECEPT IN KITCHEN AND BATH
12) VERIFY BASEBOARD HEATING CIRCUIT