Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/16/2012 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* | |
| 02/13/2012 | ELECTRIC - RECONNECT | Partial Approval | IVRS - Inspection :* 1) GROUNDING ELECTRODE CONDUCTOR TO TERMINATE TO GROUNDED CONDUCTOR 2) USE APPROVED MOUNTING SCREWS-NOT DRYWALL SCREWS 3) IN GUTTER INSTALL GROUNDED BAR 4) FINISH SUB PANEL 5) FINISH GROUNDING ELECTRODE SYSTEM AND GAS BOND 6) OK INTERIOR |
|
| 02/10/2012 | ELECTRIC - RECONNECT | Cancelled | IVRS - RI canceled | |
| 02/09/2012 | ELECTRIC - RECONNECT | Cancelled | IVRS - RI canceled | |
| 02/07/2012 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 01/30/2012 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* FRONT LIGHT: 1) EXPOSED CONDUCTORS MADE UP OUTSIDE LIGHT 2) STRAP CONDUIT BACKSIDE OF HOUSE 3) NON CODE COMPLIANT WIRING ON BACK OF UNITS 4) EXTERIOR DISCONNECT AND WIRE WAY IN DETERIORATED CONDITION 5) ENTIRE SERVICE IN DETERIORATED CONDITION 6) MISSING GROUNDING ELECTRODE SYSTEM 7) BROKEN RECEPTS 8) INTERIOR PANEL NOT CODE COMPLIANT AT TIME OF INSTALL 9) NUMEROUS VIOLATIONS 10) WATER HEATER NOT WIRED TO CODE 11) GFI'S NEEDED FOR REPLACED RECEPT IN KITCHEN AND BATH 12) VERIFY BASEBOARD HEATING CIRCUIT |