Permit: T11EL03208

Parcel: 120090960

Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
01/04/2012 ELECTRIC - RECONNECT Approved IVRS - Inspection :*
12/16/2011 ELECTRIC - RECONNECT Not ready for Inspection IVRS - Inspection :*
12/14/2011 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
05/04/2009 ELECTRIC - RECONNECT Denied COMMENTS FROM T09EL00894:
1) PROVIDE MINIMUM 2" RISER
2) INSTALL GROUND ROD SYSTEM
3) BOND GAS AND WATER
4) CHANGE OR PROVIDE UPGRADE PERMIT
5) SECURE #4 TO BLDG
6) PROVIDE SQUARE "D" BREAKERS TO MATCH PANEL
7) 15 AMP BREAKERS REQUIRED 14-2 WIRING
8) STORAGE ROOM ON PROPERTY LINE WILL BE TURNED INTO DNR
9) CONSULT TEP FOR POSSBLE NEW LOCATION OF SERVICE DROP
10) PROVIDE 12' CLEARANCE DROP OVER VEHICLES CONSULT WITH TEP
11) UNABLE TO OPEN MAIN DISCONNECT
12) UPGRADE REQUIRED
13) OVER 6 BREAKERS REQUIRE DISCONNECT
04/28/2009 ELECTRIC - RECONNECT Denied COMMENTS FROM T09EL00894:
1) POST HOUSE NUMBERS
2) SERVICE NOT GROUNDED
3) INTERIOR SUB PANEL MAY NOT BE USED FOR EXTERIOR USE, UPGRADE REQUIRED
4) EXTEND PRESSURE RELIEF TO GROUND WATER HEATER
5) PROVIDE WEATHERED FITTINGS AND CAP EXTERIOR GFCI
6) SMOKE ALARMS BEDROOMS