Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T11EL03025

Parcel: 133291010


Addresses:

8250 E SHILOH ST


Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Permit Number - T11EL03025

Inspection Description - ELECTRIC - RECONNECT

Inspection Status - Approved

Date Description Inspector Results Comments
01/18/2012 ELECTRIC - RECONNECT Approved IVRS - Inspection :*
11/28/2011 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SMOKE DETECTORS NEEDED IN ALL BEDROOMS
2) HOT (BLACK) CONDUCTORS HOOK UP TO NEUTRAL BAR AT PANEL
3) 2 WIRES AT ONE BREAKER AT PANEL
4) REPAIR CONDUIT TO CODE FROM A/C COMPRESSOR TO PANEL
5) SECURE PANEL TO WALL
6) GFI BREAKER AND WEATHER PROOF COVER NEEDED FOR OUTLET UNDER PANEL