Permit: T11EL02878

Parcel: 118032030


Addresses:

2832 W SAN JUAN TE

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
12/14/2011 ELECTRIC - FINAL Approved IVRS - Inspection :*
12/13/2011 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
1) INSTALL MISSING OUTLET COVERS IN GARAGE
2) TAPE CANNOT BE USED TO COVER BLANKS IN BREAKER PANEL NEED, PLASTIC SNAP IN TYPE
3) CEILING LIGHTS IN GARAGE MAKE CONNECTIONS IN JUNCTION BOX
11/04/2011 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MIXED BREAKER TYPES IN PANEL
2) CAP ALL UNUSED CONDUCTORS IN PANEL
3) PROTECT ALL ROMEX IN GARAGE UNDER 7' IN HEIGHT FROM PHYSICAL DAMAGE
4) OMIT ZIP CORDS FROM CEILING FANS
5) SMOKE ALARM BEDROOMS