Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/20/2011 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 12/12/2011 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SEAL UNUSED OPENING IN DEADFRONT AND LABEL CIRCUITS 2) SEAL KNOCKOUTS BOTTOM PANEL 3) NOTES 1, 3, 4 & 5 FROM PREVIOUS |
|
| 11/23/2011 | ELECTRIC - FINAL | Denied | 1. 2 WIRE OUTLETS & GROUNDED OUTLETS ON NON-GROUNDED CIRCUIT. REPLACE OUTLETS OR GFCI PROTECT HEAD OF EACH CIRCUIT. 2. OMIT 2ND CORD FROM DINING ROOM FIXTURE 3. HAZARDOUS WIRING IN CARPORT ENCLOSURE ADDITION & CLOSET. REMOVE WIRING NOT TO CODE. 4. SMOKE ALARM BEDROOMS 5. EXTERIOR WIRING TO REAR AND FRONT FLOODLIGHTS NOT WEATHER PROTECTED. 6. REMOVE LOCK FROM ELECTRICAL PANEL 7. OPEN CONDUCTORS AT HOT TUB CIRCUIT 8. MANY CIRCUITS ADDED TO PANEL. 9. ALL ADDITIONS SHOULD BE ON RECORD WITH PERMIT NOTES 1-8 REQUIRED FOR POWER. |