Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - SERVICE UPGRADE
Permit Number - T11EL02802
Inspection Description - ELECTRIC - SERVICE UPGRADE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/04/2011 | ELECTRIC - SERVICE UPGRADE | Approved | IVRS - Inspection :* | |
| 11/02/2011 | ELECTRIC - SERVICE UPGRADE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MUST USE A LISTED RISER SUPPORT-HOMEMADE OUT OF EMT NOT APPROVED 2) GROUND RODS MUST BE 6' MINIMUM APART 3) USE APPROVED CLAMP FOR #4 BARE GOING THRU -1/2" KO AT BOTTOM OF PANEL TO SECURE TO ENCLOSURE 4) BOND WATER/GAS PIPING |