Permit: T11EL02772

Parcel: 13012297A


Addresses:

3647 E ELLINGTON PL

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
04/17/2012 ELECTRIC - FINAL Approved IVRS - Inspection :*
03/07/2012 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) POST ADDRESS ON HOUSE
2) RE-ATTACH WATER BOND IN FRONT WATER PIPE
3) INSTALL SMOKE DETECTORS IN BEDROOMS MINIMUM 3' AWAY FROM COOLER VENTS
4) WATER HEATER NOT WIRED
5) PANEL FOR SERVICE HAS BEEN ALTERED, CANNOT MIX MANUFACTURERS/PARTS, MUST BE COMPLETE LISTED EQUIPMENT, KO'S NOT BUSHED BEHIND PANEL, GROUND ELECTRODE CONDUCTOR SPLICE MUST BE IRREVERSIBLE. GAS WIRE NEEDS TO BE STRAPPED TO WALL
6) LIGHT FIXTURE IN CLOSET NEEDS TO BE ENCLOSED TYPE
7) ROOM ADDITION BUILT IN BACK SHOULD BE ON RECORD
10/21/2011 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
1) LEFT MESSAGE 8:25 AM
2) PROVIDE ACCESS 9:30 AM