Permit: T11EL02690

Parcel: 123111560


Addresses:

1325 E LINDEN ST


Inspection Status: Partial Approval

Inspection History: ELECTRIC - SERVICE UPGRADE

Permit Number - T11EL02690

Inspection Description - ELECTRIC - SERVICE UPGRADE

Inspection Status - Partial Approval

Date Description Inspector Results Comments
10/27/2011 ELECTRIC - SERVICE UPGRADE Partial Approval IVRS - Inspection :*
1) ALL WORK DATED 10/25/11 HAS BEEN COMPLETED, PROVIDE PERMIT FOR A/C AS DIRECTED
10/25/2011 ELECTRIC - SERVICE UPGRADE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSTALL GROUNDING ELECTRODE PER ARTICLE 250.65 2005 NEC AND INSTALL GROUNDING ELECTRODE CONDUCTORS PER ARTICLE 250.66
NOTE: WHEN CONNECTING OLD SERVICE TO NEW SERVICE DISCONNECT CANNOT BE USED AS A JUNCTION BOX