Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/01/2011 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 10/27/2011 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) OK #1 2) STILL NEED GFI PROTECTION ON GROUND TYPE RECEPTS 3) ALSO DISCONNECT 2ND SERVICE/METER FROM UTILITY, POWER AND IF CONVERTING TO SUB PANEL |
|
| 10/17/2011 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) GROUND RODS MUST BE COMPLETELY IN EARTH FULL LENGTH-DO NOT BEND OVER 2) THERE ARE 2 METERS/SERVICES CANNOT BE INTERCONNECTED ON LOAD SIDE 3) CANNOT HAVE GROUNDED RECEPTS ON UNGROUNDED SYSTEM UNLESS GFI PROTECTED. THERE ARE BOTH TYPES OF RECEPTS THRU-OUT DWELLINGS 4) ISOLATE AND ADDRESS BOTH SERVICES, ALSO TO BE REFLECTED ON PERMIT |
|
| 10/14/2011 | ELECTRIC - FINAL | Cancelled | CANCELLED PER CONTRACTOR JAMES KINNEY #298-8844 | |
| 10/14/2011 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* |