Permit: T11EL02520

Parcel: 125071820


Addresses:

2444 E 5TH ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
10/17/2011 ELECTRIC - FINAL Approved IVRS - Inspection :*
10/13/2011 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 220 LINES, IN THE NOW ACCESSIBLE MAIN PANEL, MUST BE PROTECTED BY A DBL POLED BREAKER, NOT 2 SINGLE BREAKERS. PANEL MARKINGS SAY THESE LINES FEED THE RANGE
09/28/2011 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CHANGE ALL 3 PRONG OUTLETS, THAT ARE ON A 2 WIRE CIRCUIT BACK TO 2 PRONG OUTLETS OR MAKE THEM ALL GFI'S
2) PROVIDE PERMANENT ACCESS TO SOUTH EXTERIOR MAIN PANEL
3) INSTALL SMOKE DETECTORS PER MANUFACTURERS SPECS AND AT LEAST 3 FEET FROM A/C REGISTERS
NOTE: INSPECTION PERFORMED ON FRONT HOUSE ONLY, AS THERE IS NO SEPERATE UNIT NUMBER ON PERMIT FOR 2ND METER
09/26/2011 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) #2646 DID NOT OPEN LOCK BOX
2) PLEASE RECALL