Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/17/2011 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 10/13/2011 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 220 LINES, IN THE NOW ACCESSIBLE MAIN PANEL, MUST BE PROTECTED BY A DBL POLED BREAKER, NOT 2 SINGLE BREAKERS. PANEL MARKINGS SAY THESE LINES FEED THE RANGE |
|
| 09/28/2011 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CHANGE ALL 3 PRONG OUTLETS, THAT ARE ON A 2 WIRE CIRCUIT BACK TO 2 PRONG OUTLETS OR MAKE THEM ALL GFI'S 2) PROVIDE PERMANENT ACCESS TO SOUTH EXTERIOR MAIN PANEL 3) INSTALL SMOKE DETECTORS PER MANUFACTURERS SPECS AND AT LEAST 3 FEET FROM A/C REGISTERS NOTE: INSPECTION PERFORMED ON FRONT HOUSE ONLY, AS THERE IS NO SEPERATE UNIT NUMBER ON PERMIT FOR 2ND METER |
|
| 09/26/2011 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) #2646 DID NOT OPEN LOCK BOX 2) PLEASE RECALL |