Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/18/2011 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* | |
| 09/20/2011 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WHITE NEUTRAL WIRE HOOKED UP TO BREAKER AT PANEL 2) EXPOSED WIRE CONNECTIONS AT BACK EXTERIOR ROOM OR REMOVE 3) FIXTURE IN BACK ROOM NEEDS TO BE HUNG TO CODE OR REMOVED 4) PROTECT CONDUCTORS (WIRES) BELOW 7' OR REMOVE 5) OUTLET COVER PLATES MISSING IN BACK ROOM 6) SECURE ROMEX TO CODE OR REMOVE 7) SMOKE DETECTORS NEEDED IN ALL BEDROOMS AND RIGHT OUTSIDE BEDRIOOM 8) ELECTRICAL IN SHED TO BE BROUGHT UP TO CODE ORE REMOVED 9) NO CORD CONNECTED LIGHT ALLOWED 3' HORIZONTALLY OR 8' ABOVE BATH TUB RIM |