Permit: T11EL02391

Parcel: 119040520


Addresses:

3625 S LUNDY AV

Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
10/20/2011 ELECTRIC - RECONNECT Approved IVRS - Inspection :*
09/27/2011 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ADDED CIRCUIT TO PANEL LACKS REQUIRED WEATHERED FITTINGS TO GARAGE
2) MIXED BREAKER TYPE IN PANEL MUST MATCH PANEL TYPE
3) CIRCUIT TO GARAGE NOT TO CODE, UN-PROTECTED CONDUCTORS UNDER 7' IN HEIGHT
4) IN PROCESS OF REMOVING CEILING TILES POSSIBLE ASBESTOS AT ADHESIVE
5) UNABLE TO ENTER