Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T11EL02199

Parcel: 138230410


Addresses:

646 W CALLE RITA

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
09/15/2011 ELECTRIC - FINAL Approved IVRS - Inspection :*
09/08/2011 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REMOVE 220 OUTLET EXTERIOR SIDE OF CARPORT SHED OR BRING TO CODE
2) WIRE SPLICES AT CARPORT SHED CEILING NEED TO BE WIRE NUTED AND IN A BOX
3) EXPOSED WIRE ENDS ABOVE SERVICE PANEL, REMOVE OR TERMINATE CORRECTLY
4) WATER HEATER AND HEATER VENTS TO BE HOOKED UP BEFORE IN HABITING
08/17/2011 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SMOKE DETECTORS NEEDED IN ALL BEDROOMS
2) PHYSICAL PROTECTION NEEDED ON ALL WIRES BELOW 7'
3) EXPOSED WIRE ENDS IN CARPORT SHED
4) WEATHER TITE BOX NEEDED AT BACK PATIO
5) BLANK OFF OPEN KNOCKOUTS AT SUB PANEL AND MAIN PANEL
6) WIRE DRYER OUTLET TO CODE AT BACK PATIO HOUSING
7) HOOK UP DRYER VENT BEFORE HABITATING