Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/25/2011 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 08/11/2011 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE EXTERIOR WEATHERED FIXTURE 2) SMOKE ALARM BEDROOMS AND HALLWAYS 3) PROTECT EXPOSED ROMEX FROM PHYSICAL DAMAGE AT INTERIOR SUB PANEL 4) SECURE UTILITY BOX EXTERIOR PER CODE 5) BLANK COVERS SUB PANEL DEAD FRONT, REMOVE TAPE 6) PROVIDE SECONDARY RISER CLAMP AT SERVICE 7) PERMANENT LABEL AT METER BASE RAISED METAL LETTERS |
|
| 08/10/2011 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) SECURE UTILITY BOX 2) FRONT DOOR LOCKED AND NO ANSWER 3) RECALL |