Permit: T11EL02146

Parcel: 130192100


Addresses:

4532 E 32ND ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
11/10/2011 ELECTRIC - FINAL Approved IVRS - Inspection :*
08/16/2011 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :$
1) CORRECT ITEMS FROM PREVIOUS INSPECTION
2) OVERLOADED BOX IN LIVING ROOM
3) OPEN BOX IN BACK BEDROOM
4) UNABLE TO SEE WALL FOR OTHER OPEN BOXES
5) CORRECT ALL OTHER NON CODE COMPLIANT ISSUES
08/15/2011 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
1) CANCELLED PER WARD
08/11/2011 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) EXPOSED WIRING AT EXTERIOR TO CODE
2) CAP OFF UNUSED KNOCKOUTS AT PANEL
3) BREAKERS OF SAME MAKE AS PANEL
4) APPROPRIATE JUNCTION BOX NEEDED AT REAR OF HOUSE
5) SMOKE DETECTORS NEEDED IN ALL BEDROOMS AND ADJACENT HALL
6) ANY OTHER UNSAFE AND NOT CODE COMPLIANT ISSUES AT INTERIOR OF HOUSE