Permit: T11EL01965

Parcel: 115160330

Inspection Status: Approved

Inspection History: ELECTRIC - SERVICE UPGRADE

Date Description Inspector Results Comments
08/11/2011 ELECTRIC - SERVICE UPGRADE Approved IVRS - Inspection :*
07/25/2011 ELECTRIC - SERVICE UPGRADE Partial Approval IVRS - Inspection :*
1) FINISH BONDING PER 250.92 AND 250.66
2) NEED EQUIPMENT GROUNDING CONDUCTOR TO 100 AMP PANEL
3) CLEAN EXCESS DIRT AND FOREIGN MATERIAL FROM 100 AMP PANEL